Federal Industries 4015582 Drain Pan Heater

U.S. IMC 307.2. 2: an A/C condensate drain inside diameter should not be smaller than 3/4″ and should not be smaller than the drain pan outlet diameter. <. 3/4" condensate drain diameter is sufficient for up to 20 tons unless the drain outlet size on the unit itself is larger than 3/4″.
MasterBilt 1709534 Drain Pan Heater

warm air that passes over it, absorbing heat and moisture from the air, and condensation naturally forms. As the condensation drips off the evaporator coil it then collects in your system's drain pan and eventually drains through the condensate drain line via gravity or to a condensate pump (assuming it's properly maintained and not clogged).
Oil/Fluid Drain Pan 6L Anvil Tool

To help alleviate this potentially damaging problem, a drain pan heater should be added to your system. It connects directly to the control board and eliminates ice formation in the drain pan. The KEH063A4E is for use with outdoor Daikin Multi-Zone heat pump units including: 2MXS18NMVJU. 3MXS24NMVJU.
Master Flow 20 in. x 20 in. Drain Pan with PVC Connector 28 Gauge28DDP20X20 The Home Depot

I created this video with the YouTube Video Editor (http://www.youtube.com/editor)
Fundamentals of HVACR May 2015
Select which size pan you need and keep your home protected. Drain Pan - 32" x 36". High efficiency furnaces and evaporator coils create condensation. Sometimes it is beneficial to have a drain pan under your unit to catch any excess condensation build up. Drain Pan - 32" x 60". High efficiency furnaces and evaporator coils create condensation.
Refrigerator Defrost Drain Pan MJS62591901 parts Sears PartsDirect
However, after years of use, condensate drain pans can corrode or crack, leading to water leaks into the A/C unit and excess condensate below the drain pan, causing damage to the A/C unit and your home or commercial building. 2. Clogged or Dislodged Drain Line. If bacteria and fungus build up in the drain line, it can become clogged.
SUPCO Condensate Drain Pan, 8.34A, 7.5 qt, 12in W 48XL65CP804HD Grainger
The Diversitech 230-DPPL Large Condensate Drain Pan for mini split systems is composed of either: White UV-stabilized and reinforced polypropyline. White powder coated steel. When a mini split system operates in heat pump mode, the outdoor coil becomes the evaporator coil. Typically, condensation generates from the evaporator coil.
Drain Pan 36" x 10" Koenders

The condensate drain is typically a PVC pipe connected to the heat pump's air handler. As the heat pump operates, it pulls in warm, humid air and passes it over the evaporator coil. The coil, which is colder than the incoming air, causes the moisture in the air to condense into water droplets.
Refrigerator Condensate Drain Pan Heater Part Number 297334500 Sears PartsDirect
The drain pan collects any condensation that forms within your heat pump system. The condensate pump moves this excess water from the unit into drainage systems outside the living space(s). This helps keep moisture levels low in the home environment and prevents potential damage from occurring due to leaking components within the system.
SoLow 141821 Evap Drain Pan Heater

Heat pumps accumulate ice/frost in the heating cycle on the outdoor unit. During the defrost cycle, the ice/frost will melt and water will drain out the bot.
Norlake 034934 Heater Drain Pan, 230V, 500W Parts Town Canada
In colder climates, use a drain-pan heater, which is a small electric-resistance coil that prevents water melted during defrost from refreezing inside the outdoor unit. Without this heater, ice can build up, eventually blocking and damaging the coil. Many heat pumps designed for cold-climate use come with drain-pan heaters already installed.
Metal Drain Pan 20L Huttie

Cracked or Damaged Drain Pan. The drain pan in your heat pump works in conjunction with the drain line. Positioned beneath the evaporator coil, the drain pan collects water generated during the condensation process. The drain pipe then carries this water to an appropriate drainage point. Over time, wear and tear can lead to damage or cracks in.
Daikin KEH041A43 Drain Pan Heater

Secure Pump So It Won't Move: Secure the condensate pump to the furnace, wall, or to the floor. You want to make sure that the pump is flat and that it is below the condensate drain pan. Connect PVC Drain: Connect the 3/4" PVC drain piping from the furnace or A/C into one of the top inlets. Insert PVC drain piping at least 1-inch into the pump.
Allstar Aluminum Quick Drain Pan JOES Racing Products

For each condensate-producing HVAC component, install a corrosion-resistant drain pan under the equipment. Install a secondary drain pan of corrosion-resistant galvanized steel or durable plastic under HVAC equipment that has an evaporator coil. Install auxiliary drain lines and drain pans as required by code. See the Compliance Tab for related.
Heat pump drain pan YouTube

either drain should be able to completely empty whatever amount of water you have in the pan within seconds. if it can't, then you have a clog somewhere. also, the large drip pan below the air handler should typically be completely dry. it's there as a backup in case the drain line for the air handler clogs up. if you have any amount of water.
Climaco Heated drain pans for air conditioners

Heat from the air moves through the fins and coils and is absorbed by the cold refrigerant inside. As the temperature of the air drops below its dew point, liquid water condenses on the coils and drips into a drain pan immediately below. From there, the condensate runs out a flexible drain hose supplied with the unit.
.